Perihal Prinsip Daripada Daripada Togol Suis

May 13, 2024

Tinggalkan pesanan

In manual operation, the switch action can be divided into two stages. Stage one is to use the hand to pull the lever to the center until the lever is in a vertical position. At this time, the tip of the single-blade slider gradually moves closer to the middle until the middle position, and the compression spring is further compressed. After the lever is over the vertical position, the single-blade slider moves rapidly in the other direction under the pressure of the compression spring, and drives the lever to turn rapidly, then the moving contact plate is quickly separated from the fixed contact foot on one side and quickly connected with the fixed contact foot on the other side, which is the second stage. At this time, the separation speed of the contact is related to the size of the pressure spring and the friction between the moving parts, and the speed is very high. According to tests, the time from contact disengagement to reconnection is only about milliseconds, and the average speed is up to old millimeters of seconds. This speed is many times faster than manual or maneuvering test speed.In manual operation, the switch action can be divided into two stages. Stage one is to use the hand to pull the lever to the center until the lever is in a vertical position. At this time, the tip of the single-blade slider gradually moves closer to the middle until the middle position, and the compression spring is further compressed. After the lever is over the vertical position, the single-blade slider moves rapidly in the other direction under the pressure of the compression spring, and drives the lever to turn rapidly, then the moving contact plate is quickly separated from the fixed contact foot on one side and quickly connected with the fixed contact foot on the other side, which is the second stage. At this time, the separation speed of the contact is related to the size of the pressure spring and the friction between the moving parts, and the speed is very high. According to tests, the time from contact disengagement to reconnection is only about milliseconds, and the average speed is up to old millimeters of seconds. This speed is many times faster than manual or maneuvering test speed.

(1) Pertama daripada semua, the sesuai jenis dari suis dan penyambung sepatutnya dipilih mengikut kepada syarat dan fungsi daripada penggunaan.

(2) dinilai voltan dan arus suis dan penyambung harus pergi a tertentu margin

(3) Dalam susunan untuk mempunyai boleh dipercayai kenalan, nombor dari wayar dari hubungan dan penyambung daripada suis harus tinggalkan a pasti margin untuk selari gunakan atau sandaran.

(4) Cuba untuk pilih penyambung dengan kedudukan, so as tidak untuk masukkan salah sebab kesalahan.

(5) Hubungan pendawaian dan kimpalan boleh dipercayai, dalam susunan untuk cegah pecah garisan dan pendek laluan, the kimpalan sepatutnya di dilindungi dengan selongsong.

Hantar pertanyaan